301) Flex System Manager (FSM) / Re: ESXi host failed to go into Maintenance Mode
« on: September 30, 2013, 12:36:19 PM »
Okay I figured it out.

It was because my vCenter server was not being managed by the FSM. Once I discovered and ran inventory on it I was able to successfully relocate virtual machines and put the host into maintenance mode.

302) Flex System Manager (FSM) / ESXi host failed to go into Maintenance Mode
« on: September 30, 2013, 10:17:28 AM »
Hi all,

I'm trying to use the relocation plans to put an ESXi host in maintenance mode. I had it working before but now all of a sudden it is failing. In the error log it says "Controlling platform manager not found for target GVICESXi03"

Any ideas??

Thanks!

303) Chassis Management Module (CMM) / Re: Can't Update Ethernet Switch IPs from CMM
« on: September 20, 2013, 09:53:01 AM »
Just a quick update.

After applying this update I was able to update the Ethernet module IPs! 8)

304) Chassis Management Module (CMM) / Re: Can't Update Ethernet Switch IPs from CMM
« on: September 20, 2013, 09:06:56 AM »
Hello All,

Just recieved this new firmware package from IBM support.

IBM Chassis Management Module (CMM) Firmware v1.50.0D [2PET12] GA4 [ES].

http://www-933.ibm.com/support/fixcentral/systemx/selectFix?product=ibm%2Fsystemx%2F7893&fixids=ibm_fw_cmm_2pet12d-1.50.0d_anyos_noarch&source=dbluesearch&function=fixId&parent=Enterprise%20Chassis

NOTE: You MUST have FSM code at version 1.2.1 or LATER to update the CMM firmware to v1.50.0D.



305) Flex System Manager (FSM) / Re: SMIA Tool Locked Out!
« on: September 20, 2013, 08:49:08 AM »
Hello Brands1284,

Try this, we recently received this action plan from IBM Support as a workaround.

Happy FSMing!  ;)
=========================================================                                                                           
 To change the SMIA user ID and password, complete the                     
following steps:                                                           
                                                                           
1.  Open a management software CLI prompt and log in.                       
                                                                           
2.  Use the rmdatasource command to remove the switch from Storage         
    Control management, as shown in the following example.                 
    Note: This example does not show all of the possible options for the   
    rmdatasource command. For more information about the command, see       
    rmdatasource.                                                           
                                                                           
    smcli rmdatasource -t https -i <IP_address> -p <port_number>           
                                                                           
    where <IP_address> and <port_number> are the IP address and port of     
    the switch.                                                             
                                                                           
3.  Log in to the management software web interface.                       
                                                                           
4.  From the Home page, click the Applications tab.                         
                                                                           
5.  Under SMIA Configuration Tool, click Launch administration             
    console. The SMIA administration console window opens.                 
                                                                           
    Note:                                                                   
                                                                           
     a.  If this is the first time you launch the tool, you                 
         must download it before you can use it. If necessary, confirm     
         the browser security exceptions, and the application               
         downloads.                                                         
                                                                           
     b.  The SMIA Configuration Tool is a component                         
         of IBM? Network Advisor. The download progress window and         
         other interface elements might                                     
         be labeled as IBM Network Advisor, but the SMIA Configuration     
         Tool provides only a subset of full Network Advisor               
         functionality.                                                     
                                                                           
6. Log in to the console; then, use the console to change the               
   administrator user ID and password.                                     
                                                                           
   Important: If this is the first time you launch the tool, you must       
   change the default protocol setting from HTTP to HTTPS after you log     
   in. The IBM Flex System FC5022 16Gb SAN Switch supports only HTTP       
   Secure (HTTPS), but the default protocol for the SMIA Configuration     
   Tool is HTTP.                                                           
                                                                           
    Note: If you cannot log in to the SMIA Configuration Tool, see         
    Troubleshooting the SMIA Configuration Tool.                           
                                                                           
7.  From the management software CLI prompt, use the mkdatasource           
    command to reestablish management of the switch, as shown in the       
    following example.                                                     
                                                                           
    Note: This example does not show all of the possible options for the   
    mkdatasource command. For more information about the command, see       
    mkdatasource.                                                           
                                                                           
    smcli -user USERID -pw Passw0rd mkdatasource -c fabric -i               
    <IP_address> -t https -p 25989 -u USERID -w Passw0rd -n /interop       
                                                                           
    where <IP_address> is the IP address of the management node.           
    Note: Port 25989 is the default port number of the SMIA                 
    Configuration Tool.                                                     

306) Flex System Manager (FSM) / Re: Node Showing Out of Compliance but isn't
« on: September 04, 2013, 01:17:32 PM »
Welcome to the board!

I had a similar issue and did the following.

First ensure that the CMM firmware is current.

Next I ran inverntory on the CMM from the COMMAND LINE. Never trust a GUI  ;D.

Use this command-
USERID@gvicfsm:~> smcli collectinv -v -p "All Inventory" -i <your CMM IP>
Inventory collection percentage 0%
Inventory collection percentage 35%
Inventory collection percentage 36%
Inventory collection percentage 38%
Inventory collection percentage 69%
Inventory collection percentage 86%
Inventory collection percentage 93%
Inventory collection completed:
100%

Let me know your outcome!!

307) Chassis Management Module (CMM) / Re: Can't Update Ethernet Switch IPs from CMM
« on: August 22, 2013, 01:44:56 PM »
First thing I tried  ;).

I'm thinking because I had a previous configuration on the switches that this could be causing some of my issues. I'm not a networking guy or I might have a better idea what the solution would be.

I have just opened a PMR with IBM so I will repost when they have given me a solution.

Thanks, Brands!

308) Chassis Management Module (CMM) / Can't Update Ethernet Switch IPs from CMM
« on: August 22, 2013, 01:40:54 PM »
Hello,

Has anyone had an issue updating their ethernet switch modules via the CMM? I recently reset my CMM to defaults after an FSM rebuild and now the ethernet switches do not want to reapply their old IP.

NOTE: All other components can change their IPS no problem including SAN switches.

Please Help!   :)

309) General Discussion / Re: Hello from Northern California
« on: July 30, 2013, 09:29:10 AM »
Hello Dan!

Welcome to the site. What is your involvement with PureSystems? I'm hoping to start gaining some more valuable techies to contribute once more of these systems are rolled out.

Thanks!

-Brandon

Pages: 1 ... 19 20 [21]